CST BrandsHelpdesk Fuel SetupSite Controller Setup for Wayne Pumps

Site Controller Setup for Wayne Pumps

Before Running the Gas Setup Program

(1) The Baud Rate of the Gas Pump_____ and the Crinds______.

(2) The Blend Ratio that is setup in the pumps______.

This information should be retrieved from the customers pump supplier.

In the Gas Setup Program Setup the  “System Parameters” Section

In the Gas Setup Program Setup the  “System Parameters” Section

Set the Baud Rate for both the Gas and Crinds in this section.

If you are setting up more than one type of dispenser and only 1 gas type has card readers, then setup the gas type of the one with card readers to Gas 1.

When setting up Crinds, the COM port for the Crinds should come before the dispenser port. This means if the Crind Port is set to COM3 the Gas Port should be set to COM4.

Wayne Products should be setup as follows

Wayne Products should be setup as follows

The blends in this setup must match the blend setup in the pumps themselves.

When seting up Blended Pumps, the product setup needs to be the following:

Products 1 - 3 Unblended Pumps

Product 4 - Lowest Percentage of Blended

Product 5 - Highest Percentage Blended

Product 6 - Midgrade

The Dispenser Setup is shown below

The Dispenser Setup is shown below

This setup should be used when “NOGTP   1” is in the /home/sitecon/sc/environ.dat file.

For all other Wayne pumps

Tier: 2

Level : 1

If Smart Fuel Terminal (SMF) -

Set Alpha to Yes

Set Credit to SMF

The Misc Setup is the same for most Dispenser types. It is important to check the following

The Misc Setup is the same for most Dispenser types. It is important to check the following

The “Auth Limit” must have an amount in it or credit cards will not process at the pumps.

Additional Information

To allow a prepay on a Wayne dispenser if handle is lifted before the cashier setup a gas prepay the following needs to be set on the Decade 2400 by the pump dealer:

Mode 33, Sub 9, set to option 2

The CAT board in the EC box needs to have the jumpers to be setup at follows. Usually the only one that needs to be changed is JP29 but it doesn’t hurt to double check them all.

Running the Wayne Config Program

Before installing a new Wayne site, put this program in the /home/sitecon/sc directory, make sure it's executable with 'chmod a+x wynconf', and run it using

'./wynconf nn COMx baud', ----- e.g. './wynconf 2 COM4 4800' for the labs Wayne dispensers.

To log the information produced by the program use,

'./wynconf nn COMx baud >wynconf.txt'  This text file can be any name, ta175cfg.txt

The next version should identify if the installation is standard, i.e. NOGTP is not required. Finally for non-standard installations a gaswyn.conf file will be output that should make NOGTP unnecessary.

Below is a sample from the lab.

wynconf version 1.00

Prices - Mode 1 (Only Levels 1 & 2 Shown all levels will be displayed in *.txt file)

Price product 1 price level 1 - a03333

Price product 1 price level 2 - a03333

Price product 2 price level 1 - a00811

Price product 2 price level 2 - a00812

Price product 3 price level 1 - a03000

Price product 3 price level 2 - a03100

Price product 4 price level 1 - a01899

Price product 4 price level 2 - a01899

Price product 5 price level 1 - a02699

Price product 5 price level 2 - a02699

Price product 6 price level 1 - a01579

Price product 6 price level 2 - a01579

Price product 7 price level 1 - a06665

Price product 7 price level 2 - a06665

Price product 8 price level 1 - a06665

Price product 8 price level 2 - a06665

Price product 9 price level 1 - a09111

Price product 9 price level 2 - a00000

Grades in tanks - Mode 2

Tank grades c123451

Blend ratios - Mod 17

Blends e050101101101

Dispenser configurations

Dispenser 1 type 040 version 013

Dispenser 2 type 040 version 013

Tanks at pump positions - Mode 3

Dispenser 1 tank position d010450

Dispenser 2 tank position d020450

Grades at pump positions - mode 18

Dispenser 1 grade position g010050604

Dispenser 2 grade position g020050604

Finished

**** NOTE ****

It may be necessary to have the pump tech change the setting in the dispenser head macros, so that the “Hose to Position” is correct.  Options 24 & 51 are in the head and keep in mind of the positions on each side.  They are either “mirrored” or “Reversed”.  Normal “Hose to Position” are 3 = Unleaded (Lowest Grade) 5 Mid-Grade (Blended), 7 = Premium.

URC208-MWS-SC:/home/sitecon/sc # more gaswyn.conf

d011450

g011005640

d021450

g021005640

d030450

g030050604

d040450

g040050604